HST-Plastic

Maximum working pressure (PS): 10 bar
Test pressure(PT): PS x 1,43 / 1,5
Diaphragm: NBR, HNBR, EPDM, FPM, HYTREL, Alcryn
Standard nitrogen valve : ⅝” UNF
Installation: horizontal / vertical (nitrogen valve upward)

...Keep reading...

Compression ratio:
- recommended: P2/P0 = 2.5
- maximum: P2/P0 = 4

Mechanical life:
the number of cycles is inversely proportional to the increase of the compression ratio.
For pulsation dampener applications, the nitrogen value must be from 60% to 80% of the working pressure also in relation with the type of pump and the working temperature.

Warranty:
see dedicated page
Spare parts: see dedicated page

Also available:
- Connection with flange ANSI B16.5 or UNI/DIN
- Special connection on request
- Integral flange connection
- High pressure execution, 15bar
- Maintenance Free (HSTP-SMF)

- HSTP = PP = +0°C/+70°C
- HSTPVC = PVC-U = -5°C/+50°C
- HSTPVCC = PVC-C = -5°C/+60°C
- HSTPVDF = PVDF = -20°C/+80°C


< Back to product list