Maximum working pressure (PS): 220 bar
Test pressure (PT): PS x 1,43 / 1,3 / 1,5
Body: in AISI 316L Stainless Steel
Bladder: NBR, HNBR, EPDM, FPM, HYTREL, Butyl, Polyurethane
Standard nitrogen valve : ⅝” UNF
Installation: horizontal / vertical
(nitrogen valve upward)
...Keep reading...
Compression Ratio:
- recommended: P2/P0 = 2.5
- maximum: P2/P0 = 4
Mechanical life: the number of cycles is
inversely proportional to the increase of the compression ratio. For pulsation
dampener applications, the nitrogen value must be from 60% to 80% of the
working pressure also in relation with the type of pump and the working
temperature
Warranty: see
dedicated page
Spare parts: see dedicated page
Also available:
- Outside epoxy painted as
per standard FOX procedure or as project specification
- Connection with flange
SAE 3000 – SAE 6000, ANSI B16.5 or UNI/DIN
- Connection API spec. 6A
type 6BX
- Autoclave or Grayloc
connection
- Special connection on
request
- Integral flange
connection
- Maintenance Free
(ACSX-SMF)
-
Exotic material execution